This Barani Tech channel is for Electrical oriented topic mainly for Electrical Testing and commissioning , relay testing and configuration. In this channel we are sharing Many Topics , testing and configuration of device this all are based on my experience which i did on site. This video may be helpful for your growth in electrical field with improving your knowledge .
Main purpose of this channel to make easy understanding of electrical and easy way to study testing and commissioning , relay testing, relay configuration, ect.
Viewers are advised not to perform any practical activity based on the videos published in this channel if any practical of them without proper Guidance , without proper document, without there own Stranded of there country and without proper understating then the channel will not take any responsible for any happening.
This channel is only to get idea and knowledge in Electrical field keep watching video & Be Safe
Thank you to all of my Views
Main purpose of this channel to make easy understanding of electrical and easy way to study testing and commissioning , relay testing, relay configuration, ect.
Viewers are advised not to perform any practical activity based on the videos published in this channel if any practical of them without proper Guidance , without proper document, without there own Stranded of there country and without proper understating then the channel will not take any responsible for any happening.
This channel is only to get idea and knowledge in Electrical field keep watching video & Be Safe
Thank you to all of my Views
IDMT curve testing | REF620 relay Testing | OMICRON QUICK CMC TESTING | Overcurrent Testing
IDMT curve testing , REF620 relay Testing, OMICRON QUICK CMC TESTING ,Overcurrent Testing
full form of IDMT it’s inverse define minimum time
IDMT Curve formula they are
For normal inverse formula = TMS X 0.14 /Ir^0.02-1
For Very Inverse formula = TMS X 13.5/Ir-1
For extremely inverse formula = TMSX80/Ir^2-1
For Long Inverse formula = TMS X 120/Ir-1
On this formula TMS is time Multiple
Ir is fault current / normal current (or set current)
full form of IDMT it’s inverse define minimum time
IDMT Curve formula they are
For normal inverse formula = TMS X 0.14 /Ir^0.02-1
For Very Inverse formula = TMS X 13.5/Ir-1
For extremely inverse formula = TMSX80/Ir^2-1
For Long Inverse formula = TMS X 120/Ir-1
On this formula TMS is time Multiple
Ir is fault current / normal current (or set current)
Просмотров: 263
Видео
HOW TO CONNECTED SIMOCODE WITH TIA PORTAL SOFTWARE | UPLOAD & DOWNLOAD FILE FROM SIMOCODE RELAY
Просмотров 1 тыс.3 месяца назад
HOW TO INSTALL TIA PORTAL SOFTWARE FOR SIMOCODE RELAY COMMUNCIATION ruclips.net/video/5BwjPcszJxc/видео.html IN THIS SECETION CLEARLY EXPLANINED ABOUT SIMOCODE RELAY CONNECTION WITH TIA PORTAL SOFTWARE . AND ALSO HOW TO TAKE FILE FROM RELAY AND SEND FILE TO RELAY.
simocodo software installation | TIA Portal software installation
Просмотров 8374 месяца назад
How to install simocode siemens protection relay software step by step in tamil TIA Portal is the software used for simocode relay commiunication. simocode relay or TIA Portal software download link support.industry.siemens.com/cs/document/109811683 /simocode-es-v18-(tia-portal)?dti=0&lc=en-ID
Core Type Transformer Basic Construction
Просмотров 1 тыс.7 месяцев назад
We are going to see about construction of Three phase core type transformer. Main part of the transformer are core and winding This core is nothing but the laminated silicon steel sheets. For three phase transformer the core is in the shape of digital eight and over each vertical each phase will have LV winding near to core and next to that hv Winding. Here mostly we are going to see two main t...
Checking Fault Record for SPAM Relay | SPAM & SPAJ Trip Test
Просмотров 1,9 тыс.9 месяцев назад
Checking Fault Record for SPAM Relay , SPAM & SPAJ Trip Test for trip test is common for both spam and spaj
SPAM 140 | SPAM 150 | SPAM Relay Configuration & System Setting | How to do spam relay configuration
Просмотров 2,4 тыс.9 месяцев назад
SPAM 140 , SPAM 150 , SPAJ 140 , SPAM & SPAJ Relay Configuration & System Setting , both Spam and Spaj relay configuration will be same method for configuration. Easy way to do SPAM relay configuration and relay settings. #abbrelay #SPAM #SPAJ #RelayConfiguration #Relaysetting
SPAM 150C | HARDWARE CONFIGURATION | HOW TO CHANGE SETTING | MOTOR PROTECTION RELAY
Просмотров 2,8 тыс.10 месяцев назад
SPAM 150C , HARDWARE CONFIGURATION , HOW TO CHANGE SETTING , MOTOR PROTECTION RELAY. #spam150c #motortest
Why CT Secondary should not keep open
Просмотров 7 тыс.11 месяцев назад
DIFFERENT BETWEEN POWER TRANSFORMER AND CURRENT TRANSFORMER? WHY CT SHOULD NOT KEEP OPEN? IS IT CT WILL BLAST WHEN IT KEEP OPEN. WHAT HAPPEN IF INSULATION FAIL ON CT?
Why We use CT Secondary STAR Connection.
Просмотров 4,4 тыс.11 месяцев назад
Why We use CT Secondary STAR Connection. comparison of star and delta connection
CT Secondary Double point Earthing side effects | Mal operation of Double Earthing on CT Secondary
Просмотров 5 тыс.11 месяцев назад
CT Secondary Double point Earthing side effects | Mal operation of Double Earthing on CT Secondary
Why is a Current Transformer Secondary is always connected to Earthing
Просмотров 5 тыс.11 месяцев назад
Why is a Current Transformer Secondary is always connected to Earthing
How To Calculated Capacitor bank value
Просмотров 2,1 тыс.Год назад
How to Calculated Capacitor bank value for the outgoing feeder
DDB monitor in Easergy studio | DDB monitor in Micom relay | Online monitor for Micom relay
Просмотров 1,7 тыс.Год назад
DDB monitor in Easergy studio | DDB monitor in Micom relay | Online monitor for Micom relay
Use of Capacitor bank in Inductive load
Просмотров 1,3 тыс.Год назад
Use of Capacitor bank in Inductive load
About Apparent power active power Reactive power | VAR | W | VA
Просмотров 3,2 тыс.2 года назад
About Apparent power active power Reactive power | VAR | W | VA
Rotor Earth fault protection | part-II
Просмотров 6 тыс.2 года назад
Rotor Earth fault protection | part-II
Loss of Field Relay testing | Under excitation relay Testing
Просмотров 12 тыс.2 года назад
Loss of Field Relay testing | Under excitation relay Testing
Loss of field protection reason | Loss of field operating Region | Under excitation protection
Просмотров 9 тыс.2 года назад
Loss of field protection reason | Loss of field operating Region | Under excitation protection
Loss of Field in Generator protection | - PART 1
Просмотров 9 тыс.2 года назад
Loss of Field in Generator protection | - PART 1
100% STATOR EARTH FAULT PROTECTION IN GENERATOR
Просмотров 9 тыс.2 года назад
100% STATOR EARTH FAULT PROTECTION IN GENERATOR
95% STATOR EARTH FAULT PROTECTION IN GENERATOR
Просмотров 9 тыс.2 года назад
95% STATOR EARTH FAULT PROTECTION IN GENERATOR
Generator Stator Earth fault Protection
Просмотров 2,5 тыс.2 года назад
Generator Stator Earth fault Protection
Generator negative phase sequence protection | ANSI CODE 46
Просмотров 16 тыс.2 года назад
Generator negative phase sequence protection | ANSI CODE 46
GENERATOR POLE SLIP PROTECTION | HOW POLE SLIP PROTECTION IS DETECTED BY RELAY
Просмотров 12 тыс.2 года назад
GENERATOR POLE SLIP PROTECTION | HOW POLE SLIP PROTECTION IS DETECTED BY RELAY
GENERATOR LOW FORWARD AND REVERSE POWER PROTECTION
Просмотров 3,5 тыс.2 года назад
GENERATOR LOW FORWARD AND REVERSE POWER PROTECTION
Reverse power protection in generator
Просмотров 18 тыс.2 года назад
Reverse power protection in generator
LOW FORWARD POWER PROTECTION | CAUSE | EFFECT | PREVENTION | CALCULATION | TESTING
Просмотров 3,7 тыс.3 года назад
LOW FORWARD POWER PROTECTION | CAUSE | EFFECT | PREVENTION | CALCULATION | TESTING
You are Great👍👏😊👍👏😊👍👏😊👍👏😊_Sir G_🎉🎉🎉
Don't forget guys,like coment and share
Hi brother We already using Matching factor then how relay give trip.
Great teaching. I am learning a lot, thanks
l have a question in Cross polarization.If the operating current leads the polarizing voltage ,are we not supposed to use negative on RCA settings?
Good Morning l have questions in Cross polarization.If the operating current lead the polarizing voltage ,are not supposed to use negative on RCA settings?
Very interesting
thank you
Very interesting
Thanks, Dear🌹
Welcome 😊
Very good explanation
thank you soo much
Good
Thanks
hi can we get MCUSetup installation file
i use in Project file. it get from ABB thank you.
Thank you for this video. 1) Can you please explain settings for REM611. I urgently need to set it. 2) Also I am using 2 stages for overcurrent protection. I have set first stage as 1.2*I_FLC with IEC very inverse curve and time dial 1.12, so do I still need to set thermal overload (49) element?
i will try to make for you.
Good morning sir can you explain relay testing procedures with single phase kit
Ok soon thank you
One of my best teachers keep up good work sir, kindly arrange for your substations complete testing and commissioning for equipment and ht panels all test appreciate
you most welcome & thanks
Sir please make on timing testing of GIS
i will try to make
@@baranitech1026 ok sir I hope you will 😊
Thanks bro
your welcome bro
Sir please make video in ht motor thermal overload protection,how motor numerical relay detect thermal overload kindly explain in detail
i will try to make
Sir why negative phase sequence occur ?
due to Reactive power
One of my best teachers ,sir kindly those videos in hindi please translate in english and also put all your videos in one playlist for easy assess
i will create
Good
thank you & welcome
Thanks
welcome
Excellent
thanks & welcome
Good good brother!!
thank you bro
Mr Barani l have a problem during downloading and installing IED Products that gives me message " fail to download and install "
Same problem is arrive my system Kindly help
some time it will happens . can get connectivity package by 1.reset laptop and connect with different inter net. 2.download from ABB website. 3.Updated Updated manager and then try to download. 4.dowload from other laptop and export IED package.
Thanks a lot,Sir🥰
your most welcome
Sir. When you select the type of fault, you randomly draw the line on the circle? What actually the meaning of drawing the line amd where to start the line?
to check the boundary protection
Very informative....please upload more videos for application configuration like for goose function and communication and for TCS logics function also
sure i will and thanks for your commands
Can we change trip NC contact to NO contact ?
can not.
Sir do the ABB relay protection testing videos
general Testing video
Please prepare a video of CTS, VTS & BF and load shedding
soon i will make for you thank you
EXCELLENT SIR
thank you
Sir can you explain in briefly, how this will effect in resistive & inductive loads
i will try to make for you sir
Great explanation,thanks so much
You are welcome!
Congratulations! Very well explained
Thank you!
I am not satisfied this vedio Itna ghuma rhe ho ek line ka ans he
sorry if i am not satisfied . i will try to make other better video thank you
Sir. RED670 line differential protection please explain in tamil
i will try to make
While doing protection checks on down stream relay it's breaker is in already tripped condition any fault operated in the same relay in this scenario is LBB operation will occur in the up stream breaker
yes it will operated
Technical key option not showing, window 10, pcm600 v 2.9, relay REC670
yes for this model it will not show
Set technical key option not showing
for 670 series it will not show
Hello sir, i have encountered an error below, When copying DIGSI4 projects containing 1 or several IEC 61850 station configurations, the corresponding IEC 61850 projects are not copied automatically. Consider the corresponding hints in help. The project was found for the scd file specified.
try to export project file and SCD files
hii ji....i need your contact number ji.....
regard some training details
In digsi4 during communication with 7sj66 relay " unable to find catalog path" this type msg come what I have to do
try to check and download pset for your relay
Hello, how do you test a Hitachi electromechanical loss field relay?
i have not tested this make . but i will check for you.
Superb
your most welcome
why the check zone slope is less than bus zone. and what is the ID> setting for check zone. Please make a video on this
yes i will try to make video for you
Please i want the link of software down load of micom s1
www.se.com/il/en/product-range/61035-micom-s1-studio/#overview
Hi si have awhatsapp number ihave problem with 7sj-6225 mblf no.:7sj6225-2EB20-1HG0 .. icant commuinacte with digis using rs232 port in the front of the device give me measage :unable to conntact to device any help thank you
Nice video, thanks
your most welcome
Sir how to calculate id - 0.2pu,,,i. E what is the actual value of id in terms of actual current
= full load current / CT ratio X 0.2